CG101 General

CG101.1 Applicability.

The provisions of this chapter shall apply to the installation of nonsewered sanitation systems.

CG101.2 System requirements.

Nonsewered sanitation systems shall comply with ANSI/CAN/IAPMO/ISO 30500.

CG102 Definitions

CG102.1 General.

For purposes of this chapter, the following definitions shall apply:

CONDITIONED SPACE.

An area, room or space normally occupied and being heated or cooled for human habitation by any equipment.

NONSEWERED SANITATION SYSTEM.

A prefabricated integrated sewage treatment unit that is not connected to a public sewer or private sewage disposal system.

CG103 Installation

CG103.1 General.

The installation of nonsewered sanitation systems shall be in accordance with the manufacturer’s installation instructions and with Sections CG103.2 through CG103.7.

CG103.2 Operating conditions.

A nonsewered sanitation system in either a conditioned or unconditioned space shall be installed where the ambient temperature, ambient humidity and altitude (atmospheric pressure) are in accordance with the manufacturer’s installation instructions or product listing.

CG103.3 Clearances for servicing and maintenance.

A nonsewered sanitation system shall be located to permit access and sufficient clearance for service and maintenance. Unless otherwise specified by the manufacturer’s installation instructions, not less than 30 inches (762 mm) in depth, width and height of working space shall be provided at any access panel.

CG103.4 Backflow prevention.

A domestic water supply connection to a nonsewered sanitation system shall be protected in accordance with Section P2902.

CG103.5 Effluent storage.

Any container or vessel for the storage of effluent discharged from a nonsewered sanitation system and not integral to such system shall be installed in accordance with Section P2910.9.

CG103.6 Systems employing combustion.

A nonsewered sanitation system employing combustion shall comply with the International Mechanical Code.

CG103.7 Connection to plumbing system not required.

A nonsewered sanitation system is not required to be connected to the sanitary drainage system of the building or premises.

CG104 Manual Required

CG104.1 Operation and maintenance manual.

Nonsewered sanitation systems shall have an operation and maintenance manual provided by the manufacturer.

CG105 System Output

CG105.1 General.

The use or disposal of all substances exiting the nonsewered sanitation system shall be determined by the authority having jurisdiction.

CG106 Referenced Standards

CG106.1 General.

See Table CG106.1 for standards that are referenced in various sections of this appendix. Standards are listed by the standard identification with the effective date, the standard title and the section or sections of this appendix that reference the standard.

TABLE CG106.1 REFERENCED STANDARDS

STANDARD ACRONYM

STANDARD NAME

SECTIONS HEREIN REFERENCED

ANSI/CAN/IAPMO/ISO 30500—2019

Non-sewered sanitation systems — Prefabricated integrated treatment units — General safety and performance requirements for design and testing

CG101.2

Source and transcript record

Record Georgia · 2024 IRC · Appendix CG Nonsewered Sanitation Systems

Effective January 1, 2026 · source captured Aug 30, 2026

Transcript SHA-256 0462ed294de7286acb6e507fa803b8751cd11f3ea3a989191b630d284d556175 · text SHA-256 980fdfaf9a116a73fec9232934eec77c210a8abeeb8645a7f317e3e3d88cc15f

Adoption authority · Official amendments · ICC chapter source